﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
103	Typo in comment in bootload_tape_label.alm.	anonymous	Eric Swenson	"bootload_tape_label.alm, line 103

""   mbx + 10   18/0, 18/004000                    Connect channel LPW -> PCW

should read:

""   mbx + 10   18/0, 18/040000                    Connect channel LPW -> PCW

Ref: ""43A239854 6000B Engineering Product Specification, Part 1: 6000B I_O Multiplexer Central Jul75"",  pg. 49, figure 3.10.b, item 4.
"	defect	closed	trivial	MR12.8	Hardcore	MR12.5	fixed		