﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
227	GHM Gate ACLs grant access to non-existent or GHM-specific users/projects	Gary Dixon	Eric Swenson	"In checking ACLs on gates (suggested in STEP 6 of SIB Section 4), I found several gates with very un-Multics-like users and projects.  I doubt these should be on GHM, and certainly shouldn’t be promulgated to customer sites/systems.
 

{{{
>t>pnt_network_gate_  has a Swenson.SysAdmin.* entry.    Why?  Perhaps it should be for *.SysAdmin.*?
                      has an ACTC_SYSM.Daemon.* entry.  That certainly shouldn’t be there any more.
}}}

 
Eric Swenson says:  ""I suspect I added the Swenson.SysAdmin.* when trying to run some of the old network software (as myself).  It, of course, got dumped to the 12.7EXEC tape.  The other, clearly, came from Honeywell’s tapes.""
 

{{{
>sss>metering_gate_   has Grady.Multics.*  & various XXX.DPS-E.* entries, 
                      has project-wide for non-existent or non-Multics projects:
                                      *.MOTech *.MPO  *.TR
}}}

 
Eric says:  ""These were as we got these on the 12.3/12.5 tapes.  I haven’t 'patched' anything here.  I’ve only made changes as per tickets and agreed-upon changes.""
 "	defect	closed	major	MR12.8	Standard Library	MR12.7	fixed		