﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
441	Long running IMFT requests get aborted with no ability to extend timeout	Eric Swenson	Eric Swenson	"An IMFT output driver sends an object by running backup_dump into the transport, then sends an EOF command and waits for the remote input driver’s EOF reply, which says whether the object was loaded without errors (imft_transmit object_). The remote driver sends that reply only after backup load has loaded everything. The wait is fixed at 5 minutes: the EOF command is written with local icri.timeout = 5 * ONE MINUTE and the same value is used for the reply read.

So the sender’s 5 minutes must cover the time the receiver needs to take in and load whatever is still in transit when the sender finishes, plus backup_load ’s own time for the last entries. When that is longer, the sender reports
{{{
imft_transmit_object_: Attempt to read/write record timed out. Attempting to read from SYSTEM.
}}}

drops the connection, and defers the request, and the request fails the same way on every retry.

This was seen transferring a large subtree over dial-up (FNP) lines between two emulated systems, where the emulator let the sender run several minutes of data ahead of the receiver. (That emulator