Opened 4 years ago
Closed 3 years ago
#302 closed defect (fixed)
Administration utility "ec master new_proj" segfaults when finishing up
| Reported by: | Owned by: | Eric Swenson | |
|---|---|---|---|
| Priority: | major | Milestone: | MR12.8 |
| Component: | Administration | Version: | MR12.7 |
| Keywords: | ec master, new_proj | Cc: |
Description
Perhaps 3/4 of the instances I run "ec master new_proj" I get a segment fault after the project settings are entered and (it seems) while attempting to save the resulting table. Here is an example:
====================
Input for "Hardware" complete.
daily_summary: cut 0, warned 0, total $0.00
Error: Segment-fault error by install$|2055
(>system_library_standard>bound_install_table_)
referencing 361|0
The segment has been deleted.
r 19:19 6.388 71 level 2
Change History (2)
comment:2 by , 3 years ago
| Milestone: | MR12.7 → MR12.8 |
|---|---|
| Resolution: | → fixed |
| Status: | new → closed |
https://s3.amazonaws.com/eswenson-multics/public/mcrs/MCR10131_v1.1.pdf
Fixed in MR12.8-1056.
Note:
See TracTickets
for help on using tickets.

I'm unable to reproduce this. I've tried to create 4 projects in a row using "ec master new_proj ProjName" and each time it succeed. When you next get this error, would you please do:
And send me the contents of ticket_302.txt?